Phcog.Net logo

BROWSE ALL JOURNALS

    SEE ALL 6 JOURNALS
    Article

    Identification of Medicinal Mugua Origin by Near Infrared Spectroscopy Combined with Partial Least‑squares Discriminant Analysis

    Bangxing Han1, Huasheng Peng2, Hui Yan3 Corresponding author

    1. 1Department of Pharmaceutical Engineering, College of Biological and Pharmaceutical Engineering, West Anhui University, Anhui, Lu’an 237012.
    2. 2Department of Traditional Chinese Medicine Resources, College of Pharmacy, Anhui University of Chinese Medicine, Hefei 230012.
    3. 3Department of Biotechnology, School of Biotechnology, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212018, China Pharmacogn. Mag. A multifaceted peer reviewed journal in the field of Pharmacognosy and Natural Products.

    CORRESPONDENCE

    Hui Yan

    Department of Biotechnology, School of Biotechnology, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212018, China Pharmacogn. Mag. A multifaceted peer reviewed journal in the field of Pharmacognosy and Natural Products.

    yanh1006@163.com

    Received: 24-07-2015; Revised: 04-08-2015.

    Volume 12, Issue 46 · pp. 93–97 · PUBLISHED 2 March 2016 · DOI: 10.4103/0973-1296.177907

    View on Pharmacogn. Mag. original site ↗

    ABSTRACT

    Background: Mugua is a common Chinese herbal medicine. There are three main medicinal origin places in China, Xuancheng City Anhui Province, Qijiang District Chongqing City, Yichang City, Hubei Province, and suitable for food origin places Linyi City Shandong Province. Objective: To construct a qualitative analytical method to identify the origin of medicinal Mugua by near infrared spectroscopy (NIRS). Materials and Methods: Partial least squares discriminant analysis (PLSDA) model was established after the Mugua derived from five different origins were preprocessed by the original spectrum. Moreover, the hierarchical cluster analysis was performed. Results: The result showed that PLSDA model was established. According to the relationship of the origins‑related important score and wavenumber, and K‑mean cluster analysis, the Muguas derived from different origins were effectively identified. Conclusion: NIRS technology can quickly and accurately identify the origin of Mugua, provide a new method and technology for the identification of Chinese medicinal materials.

    KEYWORDS

    Open in new tab

    REFERENCES

    As published

    Showing references and in-text citations exactly as published.

      Cite this article

      SELECT FORMAT

      Han, B., Peng, H., & Yan, H. (2016). Identification of Medicinal Mugua Origin by Near Infrared Spectroscopy Combined with Partial Least‑squares Discriminant Analysis. Pharmacognosy Magazine, 12(46), 93–97. https://doi.org/10.4103/0973-1296.177907