Phcog.Net logo

BROWSE ALL JOURNALS

    SEE ALL 6 JOURNALS
    Article

    Measurement of invasive blood pressure in rats

    Subramani Parasuraman1, Ramasamy Raveendran1 Corresponding author

    1. 1Department of Pharmacology, Jawaharlal Institute of Postgradute Medical Education and Research, Pondicherry, India ABSTRACT Blood pressure (BP) is one of the vital parameters used to assess the cardiovascular functions of a mammal. BP is commonly recorded using invasive, noninvasive, and radio telemetry methods, but invasive blood pressure (IBP) recording is considered the gold standard. IBP provides a direct indication of the effect of the investigational products on the circulatory system. Recording the IBP in rodents is an essential part of the preliminary screening of any product to determine its effect on the cardiovascular system. The present article describes the measurement of the IBP in Wistar rats/Sprague Dawley rats. Key words: Carotid artery, invasive blood pressure, tracheostomy.

    CORRESPONDENCE

    Subramani Parasuraman

    Department of Pharmacology, Jawaharlal Institute of Postgradute Medical Education and Research, Pondicherry, India ABSTRACT Blood pressure (BP) is one of the vital parameters used to assess the cardiovascular functions of a mammal. BP is commonly recorded using invasive, noninvasive, and radio telemetry methods, but invasive blood pressure (IBP) recording is considered the gold standard. IBP provides a direct indication of the effect of the investigational products on the circulatory system. Recording the IBP in rodents is an essential part of the preliminary screening of any product to determine its effect on the cardiovascular system. The present article describes the measurement of the IBP in Wistar rats/Sprague Dawley rats. Key words: Carotid artery, invasive blood pressure, tracheostomy.

    parasuphd@gmail.com

    Volume 3, Issue 2 · pp. 87–93 · PUBLISHED 2010 · DOI: 10.4103/0976-500X.95521

    View on J Pharmacol. Pharmacother. original site ↗

    ABSTRACT

    Blood pressure (BP) is one of the vital parameters used to assess the cardiovascular functions of a mammal. BP is commonly recorded using invasive, noninvasive, and radio telemetry methods, but invasive blood pressure (IBP) recording is considered the gold standard. IBP provides a direct indication of the effect of the investigational products on the circulatory system. Recording the IBP in rodents is an essential part of the preliminary screening of any product to determine its effect on the cardiovascular system. The present article describes the measurement of the IBP in Wistar rats/Sprague Dawley rats.

    KEYWORDS

    Open in new tab

    REFERENCES

    As published

    Showing references and in-text citations exactly as published.

      Cite this article

      SELECT FORMAT

      Parasuraman, S., & Raveendran, R. (2010). Measurement of invasive blood pressure in rats. Journal of Pharmacology and Pharmacotherapeutics, 3(2), 87–93. https://doi.org/10.4103/0976-500X.95521