Measurement of invasive blood pressure in rats
Subramani Parasuraman1★, Ramasamy Raveendran1★ Corresponding author
- 1Department of Pharmacology, Jawaharlal Institute of Postgradute Medical Education and Research, Pondicherry, India ABSTRACT Blood pressure (BP) is one of the vital parameters used to assess the cardiovascular functions of a mammal. BP is commonly recorded using invasive, noninvasive, and radio telemetry methods, but invasive blood pressure (IBP) recording is considered the gold standard. IBP provides a direct indication of the effect of the investigational products on the circulatory system. Recording the IBP in rodents is an essential part of the preliminary screening of any product to determine its effect on the cardiovascular system. The present article describes the measurement of the IBP in Wistar rats/Sprague Dawley rats. Key words: Carotid artery, invasive blood pressure, tracheostomy.
CORRESPONDENCE
Subramani Parasuraman
Department of Pharmacology, Jawaharlal Institute of Postgradute Medical Education and Research, Pondicherry, India ABSTRACT Blood pressure (BP) is one of the vital parameters used to assess the cardiovascular functions of a mammal. BP is commonly recorded using invasive, noninvasive, and radio telemetry methods, but invasive blood pressure (IBP) recording is considered the gold standard. IBP provides a direct indication of the effect of the investigational products on the circulatory system. Recording the IBP in rodents is an essential part of the preliminary screening of any product to determine its effect on the cardiovascular system. The present article describes the measurement of the IBP in Wistar rats/Sprague Dawley rats. Key words: Carotid artery, invasive blood pressure, tracheostomy.
Volume 3, Issue 2 · pp. 87–93 · PUBLISHED 2010 · DOI: 10.4103/0976-500X.95521
View on J Pharmacol. Pharmacother. original site ↗
ABSTRACT
Blood pressure (BP) is one of the vital parameters used to assess the cardiovascular functions of a mammal. BP is commonly recorded using invasive, noninvasive, and radio telemetry methods, but invasive blood pressure (IBP) recording is considered the gold standard. IBP provides a direct indication of the effect of the investigational products on the circulatory system. Recording the IBP in rodents is an essential part of the preliminary screening of any product to determine its effect on the cardiovascular system. The present article describes the measurement of the IBP in Wistar rats/Sprague Dawley rats.
KEYWORDS
REFERENCES
As publishedShowing references and in-text citations exactly as published.
Cite this article
SELECT FORMAT
Parasuraman, S., & Raveendran, R. (2010). Measurement of invasive blood pressure in rats. Journal of Pharmacology and Pharmacotherapeutics, 3(2), 87–93. https://doi.org/10.4103/0976-500X.95521