Phcog.Net logo

BROWSE ALL JOURNALS

    SEE ALL 6 JOURNALS
    Article

    Simultaneous determination of five marker compounds in Xuanfu Daizhe Tang by high-performance liquid chromatography coupled with diode array detection for quality control

    Kunming Qin2,3, Bin Wang3, Hao Cai2, Weidong Li2, Zhongqing Yao3, Xingde Zhang2, Tulin Lu2, Baochang Cai2,3 Corresponding author

    1. 1Engineering Research Center of State Ministry of Education for Standardization of Chinese Medicine Processing, Nanjing University of Chinese Medicine, Nanjing 210029, China.
    2. 2Nanjing Haichang Chinese Medicine Group Corporation, Nanjing 210061, PR, China.

    CORRESPONDENCE

    Kunming Qin

    Nanjing Haichang Chinese Medicine Group Corporation, Nanjing 210061, PR, China.

    Received: 27-12-2011; Revised: 26-02-2012.

    Volume 8, Issue 32 · pp. 250–255 · PUBLISHED 22 November 2012 · DOI: 10.4103/0973-1296.103647

    View on Pharmacogn. Mag. original site ↗

    ABSTRACT

    Background: Xuanfu Daizhe Tang (XDT) is a classical traditional Chinese medicinal prescription that has been widely used for treating digestive system illnesses for hundreds of years. Materials and Methods: In this study, a simple and sensitive high‑performance liquid chromatography coupled with diode array detection (HPLC‑DAD) method was established for the simultaneous determination of five marker compounds in XDT including chlorogenic acid, glycyrrhizic acid, ginsenoside Rg1, ginsenoside Rb1 and ginsenoside Re, for quality control of this well‑known traditional Chinese medicine (TCM). Results: These compounds were separated in less than 130 min using a YMC C18 column with a gradient elution system of acetonitrile and 0.1% phosphoric acid water solution at a flow rate of 1 ml/min. All calibration curves of standard components showed good linearity with R2>0.9991. Limit of detection and limit of quantification varied from 0.11 to 4.3 μg/ml and 0.20 to 11.6 μg/ml, respectively. The relative standard deviations (RSDs) of the intra‑day and inter‑day experiments were less than 4.72 and 5.48%, respectively. The accuracy of recovery test ranged from 95.0 to 105.0% with RSD values 1.28‑ 4.32%. Conclusion: The validated method is simple, reliable, and successfully applied to determine the contents of the selected compounds in XDT for quality control.

    KEYWORDS

    Open in new tab

    REFERENCES

    As published

    Showing references and in-text citations exactly as published.

      Cite this article

      SELECT FORMAT

      Qin, K., Wang, B., Cai, H., Li, W., Yao, Z., Zhang, X., Lu, T., & Cai, B. (2012). Simultaneous determination of five marker compounds in Xuanfu Daizhe Tang by high-performance liquid chromatography coupled with diode array detection for quality control. Pharmacognosy Magazine, 8(32), 250–255. https://doi.org/10.4103/0973-1296.103647