Phcog.Net logo

BROWSE ALL JOURNALS

    SEE ALL 6 JOURNALS
    Article

    Simultaneous determination of nine marker compounds in the traditional Korean medicine, Dangguisu‑san by high‑performance liquid chromatography

    Chang‑Seob Seo1, Hyeun‑Kyoo Shin1 Corresponding author

    1. 1Herbal Medicine Formulation Research Group, Herbal Medicine Research Division, Korea Institute, 1672 Yuseongdae‑ro, Yuseong‑gu, Daejeon, 305‑811, Republic of Korea.

    CORRESPONDENCE

    Hyeun‑Kyoo Shin

    Herbal Medicine Formulation Research Group, Herbal Medicine Research Division, Korea Institute, 1672 Yuseongdae‑ro, Yuseong‑gu, Daejeon, 305‑811, Republic of Korea.

    hkshin@kiom.re.kr

    Received: 05-08-2014; Revised: 18-09-2014.

    Volume 11, Issue 43 · pp. 555–561 · PUBLISHED 10 July 2015 · DOI: 10.4103/0973-1296.160457

    View on Pharmacogn. Mag. original site ↗

    ABSTRACT

    Background: Dangguisu-san (DGSS) has been widely used to treat ecchymosis, blood stagnation and pain resulting from physical shock in Korea. Objective: A high‑performance liquid chromatography– photodiode array detection (HPLC–PDA) method for simultaneous analysis of nine components, albiflorin (1), paeoniflorin (2), liquiritin (3), nodakenin (4), coumarin (5), liquiritigenin (6), cinnamic acid (7), cinnamaldehyde (8), and glycyrrhizin (9) in DGSS extract has been developed for the first time. Materials and Methods: The analytical column for separation of the nine constituents used a Gemini C18 column kept at 40°C by the gradient elution with 1.0% (v/v) acetic acid in water and 1.0% (v/v) acetic acid in acetonitrile as mobile phase. The flow rate was 1.0 mL/min and the injection volume was 10 µL. Results: Calibration curves of all compounds showed good linearity (r2 ≥ 0.9999) within the test ranges. The limits of detection and quantification for all analytes were 0.01–0.27 µg/mL and 0.04–0.89 µg/mL, respectively. All recoveries of the nine marker compounds were 96.62–102.47% with relative standard deviations (RSD) <1.72%. The RSDs of intra‑day and inter‑day precision were <1.32% and 1.61%, respectively. The amounts of the nine marker components ranged from 0.10 mg/g to 13.71 mg/g. Conclusion: The developed and validated HPLC–PDA method may help for the quality control of DGSS.

    KEYWORDS

    Open in new tab

    REFERENCES

    As published

    Showing references and in-text citations exactly as published.

      Cite this article

      SELECT FORMAT

      Seo, C., & Shin, H. (2015). Simultaneous determination of nine marker compounds in the traditional Korean medicine, Dangguisu‑san by high‑performance liquid chromatography. Pharmacognosy Magazine, 11(43), 555–561. https://doi.org/10.4103/0973-1296.160457