Phcog.Net logo

BROWSE ALL JOURNALS

    SEE ALL 6 JOURNALS
    Article

    Liquid Chromatography‑diode Array Detector‑electrospray Mass Spectrometry and Principal Components Analyses of Raw and Processed Moutan Cortex

    Xian-Mei Deng, Jiang-Yong Yu, Meng-Jin Ding, Ming Zhao, Xing-Yang Xue, Chun-Tao Che, Shu-Mei Wang, Bin Zhao

    Jiang Meng Department of Traditional Chinese Medicine, Guangdong Pharmaceutical University, Guangzhou, 510006.

    Volume 12, Issue 45 · pp. 50–56 · PUBLISHED 2016 · DOI: 10.4103/0973-1296.176046

    View on Pharmacogn. Mag. original site ↗

    ABSTRACT

    Background: Raw Moutan Cortex (RMC), derived from the root bark of Paeonia suffruticosa, and Processed Moutan Cortex (PMC) is obtained from RMC by undergoing a stir‑frying process. Both of them are indicated for different pharmacodynamic action in traditional Chinese medicine, and they have been used in China and other Asian countries for thousands of years. Objective: To establish a method to study the RMC and PMC, revealing their different chemical composition by fingerprint, qualitative, and quantitative ways. Materials and Methods: High‑performance liquid chromatography coupled with diode array detector and electrospray mass spectrometry (HPLC‑DAD‑ESIMS) were used for the analysis. Therefore, the analytes were separated on an Ultimate TM XB‑C18 analytical column (250 mm × 4.6 mm, 5.0 μm) with a gradient elution program by a mobile phase consisting of acetonitrile and 0.1% (v/v) formic acid water solution. The flow rate, injection volume, detection wavelength, and column temperature were set at 1.0 mL/min, 10 μL, 254 nm, and 30°C, respectively. Besides, principal components analysis and the test of significance were applied in data analysis. Results: The results clearly showed a significant difference among RMC and PMC, indicating the significant changes in their chemical compositions before and after the stir‑frying process. Conclusion: The HPLC‑DAD‑ESIMS coupled with chemometrics analysis could be used for comprehensive quality evaluation of raw and processed Moutan Cortex.

    KEYWORDS

    Open in new tab

    REFERENCES

    As published

    Showing references and in-text citations exactly as published.

      Cite this article

      SELECT FORMAT

      Deng, X., Yu, J., Ding, M., Zhao, M., Xue, X., Che, C., Wang, S., & Zhao, B. (2016). Liquid Chromatography‑diode Array Detector‑electrospray Mass Spectrometry and Principal Components Analyses of Raw and Processed Moutan Cortex. Pharmacognosy Magazine, 12(45), 50–56. https://doi.org/10.4103/0973-1296.176046