Phcog.Net logo

BROWSE ALL JOURNALS

    SEE ALL 6 JOURNALS
    Article

    Determination of Isoorientin Levels in Rat Plasma by Ultra‑High Performance Liquid Chromatography Coupled with Diode Array Detector and Its Application to a Pharmacokinetic Study

    Doan Nguyen Kieu Trang1, Yu Chul Kim2, Seung‑Hwan Kwon3, Choon‑Gon Jang3, Han‑Joo Maeng1 Corresponding author

    1. 1Gachon Institute of Pharmaceutical Sciences, College of Pharmacy, Gachon University, Yeonsu‑gu, Incheon, Republic of Korea.
    2. 2Department of Pharmaceutical Engineering, Inje University, Gimhae, Republic of Korea.
    3. 3Department of Pharmacology, School of Pharmacy, Sungkyunkwan University, Suwon, Republic of Korea.

    CORRESPONDENCE

    Doan Nguyen Kieu Trang

    Gachon Institute of Pharmaceutical Sciences, College of Pharmacy, Gachon University, Yeonsu‑gu, Incheon, Republic of Korea.

    hjmaeng@gachon.ac.kr

    Received: 08-02-2018; Revised: 09-03-2018.

    Volume 15, Issue 60 · pp. 81–86 · PUBLISHED 23 January 2019 · DOI: 10.4103/pm.pm_68_18

    View on Pharmacogn. Mag. original site ↗

    ABSTRACT

    Objective: The aim of this study is to develop a specific and reproducible ultra‑high‑performance liquid chromatography‑diode array detector (UHPLC‑DAD) based method to quantify isoorientin in rat plasma and to apply the devised method to a pharmacokinetic study in rats. Materials and Methods: Simple protein precipitation with methanol was utilized to extract isoorientin and rutin (the internal standard) from rat plasma. Analytes were separated on an UHPLC Phenomenex Luna Omega Polar C18 column (100 mm × 2.1 mm, 1.6 µm) by gradient elution using a mobile phase containing 1% aqueous acetic acid and 100% acetonitrile at the flow rate of 0.25 mL/min. Results: The developed UHPLC‑DAD method showed good linearity (R2 = 0.9993) over the concentration range 20–5000 ng/mL with a lower limit of quantification of 20 ng/mL. Intra‑ and inter‑day precisions were <10.7% and accuracy were within the range of 89.4%–101.3%. The recovery of isoorientin from plasma was in acceptable range (89.4%–95.5%). The devised method was successfully applied to a pharmacokinetic study after a single oral administration of isoorientin to rats. Conclusion: This is the first report of a simple, rapid, and cost‑effective UHPLC‑DAD‑based method for quantifying isoorientin in rat plasma and its application to a pharmacokinetic study.

    KEYWORDS

    Open in new tab

    REFERENCES

    As published

    Showing references and in-text citations exactly as published.

      Cite this article

      SELECT FORMAT

      Trang, D. N. K., Kim, Y. C., Kwon, S., Jang, C., & Maeng, H. (2019). Determination of Isoorientin Levels in Rat Plasma by Ultra‑High Performance Liquid Chromatography Coupled with Diode Array Detector and Its Application to a Pharmacokinetic Study. Pharmacognosy Magazine, 15(60), 81–86. https://doi.org/10.4103/pm.pm_68_18